meas_fall :
Measurement of the time instants of xreal-typed signal’s falling events.
The meas_fall
primitive measures the time instants when an xreal-typed signal in
has the (N+k*P)-th event falling below a given threshold after a specified delay, where k is 0, 1, 2, and so on. The output is a real-typed value indicating the absolute time of each event. The threshold, triggering count N, period P, and delay are defined by the parameters threshold
, times
, period
, and delay
, respectively. When the parameter times
is less than or equal to 0, the primitive updates the measurement whenever in
falls below the threshold after the delay. It is equivalent to the meas_cross
primitive with the parameter direction
set to -1
.
Input/Output Terminals
Name | I/O | Type | Description |
out | output | real | measurement output |
in | input | xreal | input signal |
Parameters
Name | Type | Default | Unit | Description |
threshold | real | 0.0 | None | threshold level |
delay | real | 0.0 | seconds | triggering delay |
times | integer | 0 | None | triggering count |
period | integer | 0 | None | triggering period |