xbit_to_xreal

xbit_to_xreal :
An xbit-to-xreal connector.

The xbit_to_xreal primitive converts an xbit-type signal to an xreal-type signal. The digital level of the input signal is converted to an analog level, defined by the conversion level parameters: level0 and level1.

The parameters level0 and level1 define the conversion levels of logic 0 and logic 1, respectively. The parameters rise_time and fall_time define the finite rise and fall times of the 0-to-1 and 1-to-0 transitions, respectively.

The parameter delay specifies the inertial delay of the primitive. In other words, if a new input event arrives before the previous event finishes its transition, the new event’s transition will override the current transition.

The parameters valueX and valueZ define the mapped values of logic X and logic Z, respectively. For example, if valueX is set to 0, all input values corresponding to logic X are treated as logic 0. Note that by default, the primitive ignores the logic X and logic Z values of the input and retains the last output value.

Input/Output Terminals

Name I/O Type Description
out output xreal xreal-type output
in input xbit xbit-type input

Parameters

Name Type Default Unit Description
width integer 1 None connector bit-width
level0 real 0.0 None conversion level for logic 0
level1 real 1.0 None conversion level for logic 1
rise_time real 0.0 seconds rise transition time
fall_time real 0.0 seconds fall transition time
delay real 0.0 seconds inertial delay
valueX logic 1’bx None mapped value of logic X
valueZ logic 1’bz None mapped value of logic Z
« xbit_to_real_var