real_to_bit_var :
: A real-to-bit connector with variable logic-1 and logic-0 levels.
The real_to_bit_var
primitive converts a real-type signal to a bit-type signal with variable logic-1 and logic-0 levels. The threshold level required to convert the analog level of the input in
to a digital level of the output out
is computed as a mid-level between the two real-type inputs: level1
and level0
.
The parameter strength
defines the driving strength of the bit-type output signal (e.g. 4 for weak
, 5 for pull
, 6 for strong
, and 7 for supply
).
Input/Output Terminals
Name | I/O | Type | Description |
out | output | wire | bit-type output |
in | input | real | real-type input |
level0 | input | real | conversion level for logic 0 |
level1 | input | real | conversion level for logic 1 |
Parameters
Name | Type | Default | Unit | Description |
strength | integer | 6 | None | driving strength (0~7) |